FAQs
Sales
How can I get more information about icon products?
icon analyser brochures and white papers are available for download in the support section. If you need more detailed information please contact our Sales Department or an icon distributor in your region.
How do I place an order with icon?
To place an order with icon, get in touch with our Sales Department or an icon distributor in your region for a quotation.
Delivery
How long does it take for an analyser to be delivered?
Delivery estimates depend on a variety of factors, including the type of analyser ordered and the order amount. For an accurate delivery estimate, contact our sales team or your local icon distributor for a budget quotation.
How quickly can spares be delivered for icon analysers?
Each spare part has a different lead time and delivery estimate when coming from the UK. Get in touch with your local icon distributor, who should have a local stock of icon spares.
Support
How can I get spare parts for an icon analyser?
Spare parts and servicing for icon analysers are locally provided by authorised icon distribution networks. Please contact an icon distributor in your region.
Who provides servicing for icon analysers?
Spare parts and servicing for icon analysers are locally provided by authorised icon distribution networks. Please contact an icon distributor in your region.
Why do I need to buy spares from icon?
Many icon spare parts are factory configured and tested, to ensure they are reliable and operate correctly. If spares are purchased externally, there is no way to ensure this reliability.
Does icon have an analyser spares list available?
Yes. You can find a spares list in the analyser manuals. You can also contact the icon Sales Department, or an icon distributor in your region.
Can icon test samples before analyser purchase?
Yes - if you are unsure of your application, or simply want added confidence that the icon solution will deliver for you, you can send samples to icon where they will be run on a factory analyser. A report will then be delivered to you.
Technical
Do icon analysers have a multi stream option?
Yes. Stream switching control can be assigned to any of the following selectable modes:
- Digital Input (up to 2 streams)
- Modbus (up to 3 streams)
- OPC (up to 3 streams)
- Internal Stream Switching Table (up to 3 streams)
Each stream can be individually named and can have their own ASTM method assigned from the internal stream switching table or over Modbus. An additional validation stream (with an optional dedicated inlet and internal validation stream selection valve) is also available and is controlled independently of the process stream switching modes selected above.
Are icon analysers ATEX, IECEx, TIIS, EAC, or ETL certified?
Yes. All icon products are approved to give absolute confidence and peace of mind in hazardous areas.
Do icon analysers have ATEX/IECEx group IIC certification?
ATEX/IECEx group IIC certification level is not available – and is usually not necessary. Zone 1, group IIB+H2 T4 is offered and will be sufficient where acetylene is not present, as can be expected in a refinery installation.
Do icon analysers have a touch screen?
Yes. All icon analysers are equipped with a 17” armoured glass wipe-clean touch-screen and intuitive multi-lingual graphic user interface.
What is the icon Cloud/Pour combined analyser?
The icon Cloud/Pour combined analyser is an adaptation of the icon Freeze Point analyser. It is used to measure very low cloud points and pour points, without the need for chilled water. For other cloud point and pour point requirements, visit the icon Cloud Point analyser or icon Pour Point analyser pages.
What is the accuracy of icon analysers?
‘Accuracy' is not a relevant metric for online physical property analysers, and is controlled by the quality of on-site analyser calibration; a perfect calibration will provide perfect accuracy. The important metric for comparing physical property analysers is repeatability - repeatability for all icon analysers is equal to or better than the repeatability criteria of the relevant test method. For individual analysers, information on repeatability can be found in the analyser brochures.
Are icon analysers NACE compliant?
icon analysers are NACE compliant. Provided the internal sample pressure is kept to below 65 psi(a), the analysers fall within the permitted exclusions of the NACE standard and so comply without special or additional material testing/certification. NACE MR0175/ISO15156 certificates are not offered for most analysers, as certification is not required for compliance. For the icon Colour/Opacity analysers, NACE certification is available as an option.
Applications
What does the icon Vapour Pressure analyser do?
The icon Vapour Pressure analyser measures vapour pressure - the pressure exerted by a vapour in equilibrium above a liquid, at a specific temperature and vapour-liquid ratio. Vapour pressure is a measurement of volatility which is used in gasoline, LNG condensate, crude oil, and liquefied petroleum gas production. This is important particularly for blending control and for finding safe storage conditions.
What does the icon Cloud Point analyser do?
The icon Cloud Point analyser determines the lowest temperature at which a fuel may be used without wax formation. This indicates the lowest ambient temperature at which a diesel fuel can be used.
What does the icon Flash Point analyser do?
The icon Flash Point analyser measures the lowest temperature at which a diesel or kerosene fuel will form a flammable vapour mixture with the air. This is useful for finding safe storage temperatures, and for the handling of these fuels.
What does the icon Colour Opacity analyser do?
The icon Colour Opacity analyser measures contamination, purity, and clarity of a sample. Many petroleum products have colour as part of their specification – the icon analyser provides accurate measurements and can duplicate a range of standard visual colour comparison tests. It is also particularly good at detecting dye colour and product contamination in pipeline applications.
The icon analyser can measure opacity and colour simultaneously and perform concentration measurements based on light absorption at single or multiple wavelengths.
What does the icon Freeze Point analyser do?
The icon Freeze Point analyser indicates the lowest temperature at which aviation jet fuel may be used.
What does the icon Pour Point analyser do?
The icon Pour Point analyser measures the lowest ambient temperature at which a fuel oil can be used. This is important for storage, and for transferring product through pipelines.
What does the icon Viscometer analyser do?
The icon Viscometer analyser measures the dynamic viscosity of a range of petroleum products. Kinematic viscosity can also be calculated, using an optional internal density transducer.
Accurately measuring the viscosity of petroleum products is important to meet final blend specifications - without having to make costly blend adjustments later in the process.
What does the icon Distillation analyser do?
The icon Distillation analyser measure individual boiling points or full boiling ranges of petroleum products, from light to middle distillate ranges.
This provides information about fuel composition, properties, and characteristics when in storage or in use. It also serves as an indicator of fuel volatility, which is directly related to the performance and pollutant emissions of engines.
What does the icon Cetane Number analyser do?
The icon Cetane Number analyser is the first and only online process analyser to measure cetane number. This measures the combustion properties/quality or performance of diesel and biodiesel fuel. The higher the cetane number, the better the fuel burns.
The measurements also include the effects of Cetane improvers, enabling real-time control.
What does the icon Ethanol Blend Optimiser do?
The icon Ethanol Blend Optimiser accurately blends specific volumes of ethanol into gas streams going into online analysers. The move to biofuels means that many gasoline specifications require ethanol addition at specific percentages, depending on location and marketing specifications.
Ethanol has an impact – called a ‘boost’ – on product specifications. This boost is sample specific, and the BOB (Blendstock for Oxygenate Blending) must cope with the worst-case boost scenario. The icon Ethanol Blend Optimiser allows for much higher precision in this blending process, allowing the analysis of the fuel with ethanol added rather than having to predict how the fuel will behave.
How can I find the Viscosity Index using the icon Viscometer analyser?
To calculate the viscosity index, two icon Viscometer analysers are required. The dynamic viscosity is measured at two different temperatures (40°C and 100°C), and the kinematic viscosity is calculated using a density signal. One analyser (the ‘master’ or primary analyser) will calculate the viscosity index from these kinematic viscosities, and can then output this measurement.
Methods
How does the Icon Vapour Pressure analyser work?
The icon Vapour Pressure analyser uses the piston-expansion principle to measure vapour pressure, in line with the latest vapour pressure test methods. It is compatible with any required ASTM test method and allows for single and/or multiple expansions.
For more information, visit the Vapour Pressure analyser page.
What ASTM methods can be performed with the icon Vapour Pressure Analyser?
Directly applicable standard test methods include ASTM D5191, D6378, D6897, and D6377.
Correlatable standard test methods include ASTM D323, D4953, D5190, D5188 and D5482.
For more information, download the Vapour Pressure brochure.
How does the icon Cloud Point analyser work?
A small amount of sample is cooled until the cloud point is reached - this point is detected by an optical detector. Cooling is done using a Peltier-based thermoelectric cooler, and if the sample is too cold the Peltier control can be reversed to warm it.
For more information, visit the Cloud Point analyser page.
What ASTM methods can be performed with the Cloud Point analyser?
The obtained results are compatible with those of standard cloud point test methods such as ASTM D2500 and ASTM D5771/2/3.
How does the icon Flash Point analyser work?
The sample is heated while a test spark is applied above – until a positive spark is detected. This flash point is detected by a highly sensitive low-mass thermocouple.
For more information, visit the Flash Point analyser page.
What methods can be performed with the Flash Point analyser?
The results are fully compatible with any standard flash point test methods, such as IP170, ASTM D56, ASTM D92, and ASTM D93.
How does the icon Colour Opacity analyser work?
A light source is passed through the sample and out to a dispersive spectrometer module, where measurements are carried out.
For more information, visit the Colour Opacity analyser page.
What methods can be performed with the Colour Opacity analyser?
The Colour Opacity analyser performs ASTM D1500 or Saybolt D156, depending on the measuring cell pathlength. Other measuring ranges are possible – contact Icon for more details.
How does the icon Freeze Point analyser work?
The icon Freeze Point analyser uses advances cryo-cooling technology (a helium cryocooler) and optical detection to measure freeze points. A small amount of the sample is trapped in the low-mass measuring cell, and is cooled until the cloud point is detected. The sample is then heated until the ‘cloud’ disappears – this is the freeze point.
For more information, visit the Freeze Point analyser page.
What ASTM methods can be performed with the Freeze Point analyser?
The obtained results are compatible with those of standard freeze point test methods – such as ASTM D2386, D5972, and D7153.
How does the icon Pour Point analyser work?
The sample is cooled until sample movement stops – this is the no-flow point. The corresponding pour point is recorded from this.
For more information, visit the Pour Point analyser page.
What ASTM methods can be performed with the Pour Point analyser?
Results are compatible with all standard no-flow and pour point test methods, including ASTM D97, D5853, D5985, AND D7346.
How does the icon Viscometer analyser work?
The icon Viscometer analyser finds the dynamic viscosity of a sample through measuring the differential pressure across a capillary tube, following the Hagen-Poiseuille principle.
For more information, visit the Viscometer analyser page.
What ASTM methods can be performed with the Viscometer analyser?
The results obtained can be directly correlated to standard test methods such as ASTM D445 AND D2270.
How does the icon Distillation analyser work?
The icon Distillation analyser carries out a full small-scale distillation on 20ml of sample. Using laser measurement technology, the volume of sample in the distillation flask and the volume recovered are accurately controlled and monitored.
For more information, visit the Distillation analyser page.
What test methods can be performed with the Distillation analyser?
The results can be correlated to a variety of standard test methods, including ASTM D86, IP123, and ISO3405.
How does the icon Cetane Number analyser work?
The sample is combusted, and a dynamic pressure wave is produced – both ignition delay (ID) and combustion delay (CD) can be determined from this measurement. Built-in equations are then able to calculate a derived cetane number (DCN).
For more information, visit the Cetane Number analyser page.
What ASTM methods can be performed with the Cetane Number analyser?
The analyser measurements correlate to all other ASTM cetane number methods such as D613, D6890, and D7668.
How does the icon Ethanol Blend Optimiser work?
The icon Ethanol Blend Optimiser uses piston cylinders to mix a combined BOB (Blendstock for Oxygenate Blending)/ethanol sample flow. This mixing system allows for a very high precision (+- 0.05%), minimising uncertainty and reducing the amount of ethanol needed.
For more information, visit the Ethanol Blend Optimiser page.
Performance
For Distributors
How can I find the latest analyser manuals?
All distributors should have access to the client portal. Analyser manuals - and other technical documents - can be found there. If you are not a current distributor and need to see an analyser manual, get in touch with your local icon distributor.
Where can I access the latest maintenance procedures?
The latest maintenance procedures can be found in the client portal, alongside other technical documentation.
I have an additional question/support query - who should I contact?
As a first step, all active distributors should have access to the client portal. Here, you can find the latest analyser manuals, maintenance procedures, technical drawings and documents, and more. Looking through these documents should answer many of your questions. If you still need more support, our support team is available to help.
Where can I find the login to the client portal?
All active distributors should have access to the client portal. If you cannot remember the login details, get in touch with the icon team.
Other
Does icon have a reference list?
Yes. Our global installed analysers list is available on request. Please contact our Sales Department or your local icon distributor.
Can icon provide consultancy?
Yes. icon experts have knowledge of the implementation of spectroscopic methods for Octane/RON/MON and aromatics measurements through the true physical property analysers like Vapour Pressure and Distillation through to Sulphur measurements. Our expertise is not confined to Gasoline Blending analytics. We offer services for Diesel, Jet and Lubes Blending. Our solutions and systems design capability ensure the blender is reliable and ready to capture that additional margin for the refinery. For more detailed information please contact our Sales team.